九九热在线免费-九九热在线免费观看-九九热在线视频观看这里只有精品-九九热这里只有国产精品-九九日韩999-九九日欧美红桃视频


DDDL-5000Q-Full automatic high current generator
  • Product name: DDDL-5000Q-Full automatic high current generator

  • Product model: DDDL-5000Q

  • Release time: 2016-03-21 11:05:08

  • Manufacturer: Great electric equipment Co., Ltd.



功能描述

Automatic temperature rise special high current generator using low power consumption and high capacity of the pressure regulating device and high permeability core manufacturing converter, and has the advantages of high output power, small volume, light weight, etc.. Mainly used for thermal relay, motor protector, contactors, breaker device, air switch, switch cabinet, circuit breaker, protection screen check busbar, cable, etc.

儀器特點(diǎn)
1, including power to adjust the pressure switch input device, voltage is output to the up flow switch input device, namely before the class, after level; after the corresponding fractions, before class; emergency stop; mutual locking (of substandard, after level does not close; after grade not, before the class not!)
2, with voltage regulator zero lock function;
3, the mutual inductor is provided with two open circuit overvoltage protection, which can avoid the signal line breaking and the current transformer two open circuit to generate high voltage;
4, up flow device body is a hole in the center of large current output can be used directly and conveniently through the conductor, sample any experiment
5, the use of special structure can effectively control the flow of the main bracket of the lifting device, the eddy current heating of the metal;
6, l surface flow device body is arranged on the outer shell of the 4 rings, convenient lifting, is arranged at the bottom of the wheel, easy to move;
Part 7, wireless control, comprises before class, after class, up flow and down flow, after class, before class, emergency stop button, control cabinet latching requirements (of substandard, after level does not close; after grade not, before the class not!) All the control system can be realized on the remote controller, and the wireless control part is embedded in the voltage and current integrated control panel display;
8, wireless control power supply using 5 battery power supply, convenient and quick change;
9, with the current source waveform monitoring Q9 head, to facilitate the monitoring of large current output waveform (can be installed oscilloscope);
10, instrument selection 160*80 digital tube display, facilitate remote (10m) wireless control of the far view, can simultaneously monitor power supply voltage, current, pressure regulator's output voltage, current, up flow output voltage and current;
11, with power-off protection function, up flow during the test, if all of a sudden loss of power again after restoration (in the control panel on the manual closing air switch is closed), pressure regulating motor automatically reset to zero (with zero instructions). Then you can do before the class, after class, up flow and down flow operation strictly avoid with impact load hold jump higher power;

12, according to the user needs to choose 5.7 inch 15 inch 10 inch screen 


技術(shù)參數(shù)
2.1 input voltage: AC380V + 10%
2.2 power: 50KVA
2.3 output current: AC0 ~ 5000A, stepless adjustable panel with digital ammeter voltmeter, LCD screen
2.4 output mode: direct
2.5 the output waveform of output current is better than the standard sine wave, burr small, power system requires the index standard, ripple coefficient is less than 0.3%. Standard sine wave.
2.6 measurement accuracy: (0.2S grade); the current can be smooth smooth and continuous adjustable accuracy is higher than 0.5. The current voltage table shows the true effective value, high precision, high stability.
2.7: RMS output current continuously adjustable;
2.8 structure: whole or separated
2.9 protection settings: overcurrent and overvoltage (primary and overcurrent protection)
Test 2.10: 2 action time: 0.001~99999.999S
1 automatic control current increases, decreases
2, 64 temperature inspection according to request by testing the temperature range.
1) temperature range: -100 to 1000 DEG C; (standard sensor temperature range: -50-300 DEG C)
2) measurement accuracy: 0 ~ 1000 degrees: + (reading * 0.5%+1) c,
-100 ~ 0 C + (read: numerical c * 0.5%+2);
3) has the function of anti high frequency interference.
4) the temperature signal input channel number is up to 8 configuration group, n = 8; (by type)
5) sensor: nickel chromium nickel silicon thermocouple (type K) (type T, J type can be customized).
Three point two
According to customer needs:
1, automatic and manual operation.
2, online display in the process of test current, voltage, transformer and the tested temperature (more), with tables and curves, and transferred to the other computers in the storage for further analysis, use the archive. Data using Excel spreadsheet format, easy to chart, curve form and data conversion between the text using word format.
3, according to the need to set the test current, the test current is stable and reliable, not affected by the system or outside factors.
4, can be set according to the requirement of the subjects of allowable temperature, system automatically adjusts the maximum current setting, when to test the set temperature display and record the moment of maximum working current, bus at the highest allowable temperature of the maximum working current (or set of temperature under the maximum working current).
5, with the transformer and the current test parts of the current, the lowest temperature and the highest value, with more than the limit value of automatic alarm function. Self protection function of over current, over current, over voltage and short circuit.
6, the same test pieces are automatically repeated large current temperature rise test, set the number of tests, test current, interval time, the current speed, the maximum allowable current duration. Finally, after the test, the device is automatically completed. Cycle test can!
7, before the test, the touch screen can be set to complete all parameters, and strive to operate simple and clear.
8, encountered over flow, over-voltage, short circuit, over temperature, pressure loss, with the necessary protection and sound and light alarm signal. For the test device is not necessary to produce destructive alarm factors, it can be issued sound and light alarm, the operator was informed of the alarm according to the actual situation to judge, to make the appropriate treatment. Within a certain period of time after the alarm, no one knows, the device automatically shut down.
Operation interface:
Five, operation instructions
1) page description
1), enter the system
2), the main menu
3), automatic test interface (according to the setting value of current automatic adjustment, automatic tracking and output current is infinitely close to the set value. From the press.
Move to the beginning of time, set the output end of time stop output or the external temperature exceeds the set temperature detection stop output)
4), parameter setting
5), manual test (size, adjustable positive current with current tracking function. Mainly used for overcurrent relay operating time)
2) setting current output
The automatic mode according to the needed current setting value set current size, set the output time, set up after the regulator will automatically adjust the output current value.
3) output time
According to the experimental requirements set high current output time, automatically stop the current output time instrument
4) overcurrent protection
According to the current size of the Chrono Trigger to set the current protection value, Chrono Trigger current value is 1.1 times for the current protection action value. Overcurrent protection, alarm instrument.
3 zero start
In order to protect the sample, the up flow from "0A" to start up flow. When the pressure regulator in the zero state, press the "start" button, contactor, instrument output, when the voltage regulator in a non null state instrument according to "closing" button, the equipment can not be closing no output.
4 current loop principle

5, temperature control: setting the temperature test point reaches the temperature, automatic stop output, can be matched with thermocouple, thermal resistance etc.. 

主站蜘蛛池模板: 国产亚洲综合网| 国产无码麻豆视频| 乱码精品一区二区三区| 色婷婷亚洲婷婷七月中文字幕 | 热久久网站| 精品人妻伦一品二品三| 91成人爽a毛片一区二区动漫| 亚洲综合色无码一| 国产精品亚洲自在线播放页码| 修理工厨房侵犯人妻系列国产| 蜜桃久久久久久久久久久| 精品无码免费一区二区三区| 天天插天天| 精品久久久久中文字幕一区 | 国产亚洲AV一二三区在线观看| 精品乱码久久久久久日本麻豆 | 国产伦精品一区二区三区视频欲| 熟女乱p网| 欧美日韩一区二区三区| 成人国产在线观看高清不卡| 国产精品扒开腿做爽爽爽A片| 麻花传媒mv在线播放高清MBA| 日本成人动漫私人影院| 无码人妻精品一区二区蜜桃网站| 大陆一级毛片国语对白| 国产熟睡乱子伦视频在线播放| 蜜桃色永久入口| 亚洲理论片在线观| 色综合天天综合网国产成人网| 苍井空免费av| 无码熟妇人妻av在线c0930 | 日韩精品无码视频免费专区| 国产白嫩精品| 欧美日本视频区| 国产欧美va欧美va香蕉在| 六月伊人| 麻豆一区二区免费视频| 中文字幕av免费专区| 亚洲ⅴ国产v天堂a无码二区 | 国产精品毛片一区二区三区在线 | 国产人久久人人人人爽|