九九热在线免费-九九热在线免费观看-九九热在线视频观看这里只有精品-九九热这里只有国产精品-九九日韩999-九九日欧美红桃视频


DDGZ-1000Single phase fault indicator tester
  • Product name: DDGZ-1000Single phase fault indicator tester

  • Product model: DDGZ-1000

  • Release time: 2018-07-19 15:05:23

  • Manufacturer: Great electric equipment Co., Ltd.



功能描述

This manual describes the fault indicator tester designed and manufactured by the Qingdao great electric equipment Co., Ltd., designed and developed according to the professional inspection outline of the power distribution line fault indicator of the national grid in 2017. The fault indicator tester is a high reliable multi closed loop control technology with high output power. Precision, high output power resolution, high stability and reliability, high conversion efficiency, low power grid pollution, constant current and constant voltage. Using SIEMENS PLC, Taiwan polyvinyl 10 inch LCD screen, software is developed independently, without input parameters, automatic test data.

 

This product control system provides perfect protection and necessary safety measures for operators, power supply equipment and power supply itself. The key circuit and the main electrical parameters are monitored in real time. Once the failure occurs, the power is shut off immediately. The risk of the user, the electrical equipment and the power supply itself is reduced to a minimum.

儀器特點

L high frequency SPWM hardware adjustment technology, fast response and stable output.

 

L high power MOS/IGBT driver, reliable operation, strong overload capacity;

 

L is suitable for various loads such as resistance, sensibility and rectification.

 

L has the protection function of overheat, overcurrent and short circuit.

 

With parameter memory function and shortcut key operation mode, it is simple and convenient to use.

 

Using SIEMENS PLC, Taiwan polyvinyl 7 inch LCD screen, software is developed independently, without input parameters, automatic test data.


技術參數

3.1 the basic requirements of the working power supply are AC 380V + 10%, and the capacity is not higher than 40kVA.

 

3.2 basic current output basic requirements

 

3.2.1 analog current amplitude (each phase): greater than 1000A.

 

3.2.2 output accuracy: less than 0.2%.

 

3.2.3 output stability: less than 0.5%.

 

3.3 basic voltage output requirements

 

3.3.1 analog voltage amplitude (each phase): greater than 10kV.

 

3.3.2 output accuracy: less than 0.5%.

 

3.3.3 output stability: less than 0.5%.

 

3.4 basic requirement of acquisition precision

 

3.4.1 acquisition precision: less than 0.1%.

 

3.4.2 frequency range: 45 ~ 55Hz.

 

3.5 basic requirements for carrying capacity

 

3.5.1 analog line perimeter (per phase): greater than 3m.

 

3.5.2 failure indicator installation: more than 60 sets.

 

3.5.3 current output power (per phase): greater than 10kVA.

 

3.5.4 voltage output power (per phase): greater than 1kVA.

 

4. analogue function description

 

4.1 load monitoring ability detection

 

4.1.1 simulate the normal operation of distribution lines:

 

A) load current simulation, and continuously output the normal load current with a maximum value of 1000A.

 

B) line voltage simulation, and continuously output the line voltage up to 10kV.

 

4.1.2 automatic detection of distribution line fault indicator is as follows: function and performance:

 

A) load current acquisition function under normal operation condition of the line, including acquisition accuracy and acquisition interval.

 

B) voltage acquisition function, including acquisition accuracy and acquisition interval.

 

C) line load power supply function.

 

D) three phase synchronization precision detection.

 

Detection of 4.2 short circuit fault identification ability

 

Simulation of interphase short-circuit fault line current and voltage changes, automatic detection of distribution line fault indicator short-circuit fault identification function, performance:

 

A) short circuit fault detection.

 

B) fault current acquisition accuracy and start error detection.

 

C) automatically determine the function of fault current alarm action value according to line load variation.

 

D) short-circuit fault current minimum duration 40ms recognition capability.

 

E) transient fault and permanent fault recognition capability.

 

F) functions such as data communication, timing, signal reset and other functions.

 

Detection of 4.3 grounding fault recognition ability

 

4.3.1 simulates different types of grounding faults:

 

A) simulate the change of line current and voltage caused by metal grounding, small resistance grounding, high resistance grounding, and arc grounding fault.

 

B) simulate the transient process of current and voltage in different grounding systems and different types of grounding faults.

 

C) the transient fault current with a maximum value of 1000A can be output.

 

D) the phase of the fault triggering time is controllable.

 

4.3.2 automatic detection of distribution line fault indicator grounding fault identification function and performance:

 

A) detection of different types of grounding faults and detection of grounding fault recognition rate.

 

B) fault current acquisition accuracy and startup error detection for small resistance grounding fault.

 

4.4 fault recording function

 

Support the recording of the current and voltage waveform of Comtrade 1999 standard recording format, compare with the waveform sent by the fault indicator, and automatically output the comparison result.

 

4.5 anti malfunction detection

 

The operation conditions such as load fluctuation, large load switching, transformer unload inrush, line closing inrush, near line fault and reclosing current are used to automatically detect the anti misoperation function of distribution line fault indicator.

 

4.6 fault case editing and execution

 

A) can edit state sequence and store according to relevant standards, such as ground fault state sequence, instantaneous short circuit fault state sequence, permanent short circuit fault state sequence and so on.

 

B) select the corresponding state sequence or fault case according to the test request, and execute the test case automatically.

 

4.7 response image recognition

 

Support distribution line fault indicator response results automatic image acquisition, identification and upload.

 

Analysis and comparison of 4.8 detection results

 

It supports automatic analysis, comparison and calculation of test results.

 

4.9 the result of detection is consistent

 

The detection result is based on the latest relevant standards of the national Power Grid Corp and the quality control and control scheme, which is consistent with the professional inspection of the network, ensuring the professional inspection of the distribution line fault indicator, the inspection before supply and the agreement of the inspection results after the arrival of the goods.

 

4.10 unified deployment of detection cases

 

Support the unified deployment of detection cases, support network professional detection report, pre supply and post delivery inspection report integration and sharing, easy to network professional testing and different provincial companies to carry out pre supply and post inspection cases, detection methods, judgment basis, and the results of the unified sharing.

 

2 upgrade and extension

 

5.1 detection project and judgment basis update

 

The corresponding testing items can be configured according to the change of the testing standards, and the basis for judging the maintenance results can be updated, so as to improve the accuracy and consistency of the test results.

 

5.2 load capacity expansion

 

It can expand the carrying capacity according to the test demand, drive the longer analog coil, and has a larger detection capability.

主站蜘蛛池模板: 无码人妻一区二区三区免费 | 国产无码免费在线视频| 国产女人乱人伦精品一区二区| 欧美精品一区二区A片免费| 久久这里只有精品久久| 邻居寂寞人妻中文字幕 | 久久亚洲精品无码av| 欧美性生交18无码| 精品日韩欧美一区传媒精品网站| 久久这里只有精品1| 国产日韩成人| 青青草国产成人99久久| 国产vr精品专区| 亚洲欧美日本人成在线观看| japanese日本护士xxx| 提供最新的在線欧美综合一区 | 欧美美女一区二区三区| 国语对白免费观看网址| 久久久久国产一区| 日本VS中国VS亚洲看无码A| 国产无人区码卡功能齐全| 久久久这里有精品999| 国产成人免费av片在线观看| 亚洲无av码一区二区三区 | 亚洲国产精品毛片AV不卡在线| 99久久免费国产精品热dvd在线观看| 日韩一区二区在线观看av| 被黑人做的白浆直流| 日本乱人| 中中文日产幕无线码| 久久久久久久久女黄9999| 亚洲AV优女天堂波多野结衣 | 亚洲亚洲人成综合网络| av天堂天堂av在线| 日韩国精品一区二区A片| 国产日韩综合| 欧美另类高清| 精品久久久久久久久AV无码| 精品国产3p一区二区三区| 91热久久免费频精品黑人99| 国产成人免费福利网站|